sentryumactive-act 30kva manual

The Sentryum Active-Act 30kVA UPS is a high-efficiency, transformerless online UPS with unity power factor, designed for flexibility and reliability in protecting critical power systems.

1.1 Overview of the Sentryum Active-Act Series

The Sentryum Active-Act series, including the 30kVA model, represents Riello’s third-generation transformerless UPS technology. Designed for flexibility and scalability, it offers high efficiency, unity power factor, and a compact footprint. Available in 10-40kVA models, it supports various power requirements and battery configurations, making it ideal for data centers and critical applications.

1.2 Importance of the Manual for Users

The manual is essential for proper installation, operation, and maintenance of the Sentryum Active-Act 30kVA UPS. It provides detailed instructions, safety guidelines, and troubleshooting tips, ensuring users can optimize performance, handle emergencies, and maintain efficiency. This guide is crucial for maximizing the UPS’s reliability and extending its operational lifespan.

Key Features and Benefits

The Sentryum Active-Act 30kVA UPS offers high efficiency, compact design, and unity power factor, ensuring reliable power protection with minimal energy loss and advanced scalability options.

2.1 Design and Flexibility

The Sentryum Active-Act 30kVA UPS features a compact footprint of 0.35m², making it ideal for space-constrained environments. Its flexible design supports non-linear loads, such as blade servers, and offers optional battery extension packs for extended runtime. The system allows for up to 8 units in parallel for scalability and redundancy, ensuring tailored solutions for diverse power needs.

2.2 Power Factor and Efficiency

The Sentryum Active-Act 30kVA UPS delivers a unity power factor, ensuring full-rated power delivery with minimal energy loss. It achieves exceptional operating efficiency of up to 96.5% in online double-conversion mode, even at low loads of 50%, making it highly efficient and suitable for applications requiring reliable power protection with reduced energy waste.

2.3 Scalability and Redundancy Options

The Sentryum Active-Act 30kVA UPS supports parallel operation of up to 8 units for enhanced redundancy and scalability. Its modular design allows for flexible battery configurations, including one or two internal battery strings and optional external packs, ensuring extended runtime and high availability for mission-critical applications.

Technical Specifications

The Sentryum Active-Act 30kVA UPS features a unity power factor, 96.5% online efficiency, and a compact footprint of 0.35m². It operates at 380/400/415V three-phase input and output.

3.1 Input/Output Ratings

The Sentryum Active-Act 30kVA UPS operates at 380/400/415V three-phase input and output, with a unity power factor (1 kW/kVA). It achieves up to 96.5% efficiency in online mode, ensuring minimal energy loss during operation. The system is designed to handle non-linear loads effectively, making it ideal for blade servers and critical power applications.

3.2 Battery and Runtime Details

The Sentryum Active-Act 30kVA UPS features 1 or 2 internal battery strings, providing a runtime of up to 6 minutes at full load. Optional battery extension packs are available to extend runtime, offering flexibility for varying power requirements; The system supports up to 8 units in parallel for enhanced redundancy and reliability.

3.3 Physical Dimensions and Footprint

The Sentryum Active-Act 30kVA UPS features a compact design with a footprint of less than 0.35m² and dimensions of 380mm x 850mm x 1025mm (W x D x H). Its volume is 0.33m³, making it space-efficient for installation in data centers or industrial environments while maintaining high performance and reliability.

Installation and Configuration

The Sentryum Active-Act 30kVA UPS offers a compact footprint of 0.35m², ensuring easy installation in various environments. It supports flexible configurations and operates efficiently across a wide temperature range, making it ideal for data centers and industrial applications.

4.1 Pre-Installation Considerations

Ensure the site meets environmental requirements, with operating temperatures up to 40°C. Verify compatibility with power supplies and communication ports. Check battery configuration options, including internal strings, and ensure proper space allocation for the compact 0.35m² footprint to facilitate smooth installation and optimal performance.

4.2 Step-by-Step Installation Guide

Begin by unpacking and inspecting the UPS for any damage. Place the unit in a suitable location with adequate ventilation. Connect the input and output power supplies as per the manual. Configure the battery strings according to load requirements. Install communication cards and connect ports. Power on the UPS and run diagnostics to ensure proper operation.

4.3 Configuration Options

The Sentryum Active-Act 30kVA UPS offers advanced configuration options, including operating mode selection (Online, Eco, or Smart Active), communication port settings (USB, RS232, RJ10), and customizable battery management. Users can also set load prioritization and redundancy parameters to optimize performance for specific applications, ensuring tailored power protection and efficiency.

Operating Modes

The Sentryum Active-Act 30kVA UPS features three primary operating modes—Online, Eco, and Smart Active—each designed to optimize performance, efficiency, and reliability for various power requirements.

5.1 Online Mode

Online Mode provides continuous double-conversion technology, ensuring high reliability and protection against power disturbances. It offers exceptional efficiency of up to 96.5%, even at low loads, while maintaining precise voltage regulation and minimizing harmonic distortion.

5.2 Eco Mode

Eco Mode optimizes energy efficiency by reducing energy waste, achieving up to 96.5% efficiency. It switches to bypass operation during stable input, minimizing harmonic distortion and ensuring reliable power protection while lowering operational costs. This mode is ideal for eco-conscious environments, balancing performance with energy savings without compromising power quality or system reliability.

5.3 Smart Active Mode

Smart Active Mode combines high efficiency with adaptive performance, automatically adjusting to load conditions. It ensures optimal power protection while maintaining energy efficiency. This mode is ideal for dynamic environments, offering seamless switching between operating modes to maximize performance and minimize energy waste, making it suitable for critical applications requiring intelligent power management.

Efficiency and Performance

The Sentryum Active-Act 30kVA UPS delivers exceptional efficiency, with state-of-the-art components like dual-core DSP processors and high-frequency inverters, ensuring optimal performance and reliability while minimizing energy loss.

6.1 Energy Efficiency Features

The Sentryum Active-Act 30kVA UPS achieves up to 96.5% efficiency in online double conversion mode, even at low loads, minimizing energy waste. Its high-frequency, three-level inverters and dual-core DSP processor optimize performance while reducing harmonic distortion, ensuring reliable power protection with minimal environmental impact.

6.2 Performance Metrics

The Sentryum Active-Act 30kVA UPS delivers exceptional performance with up to 96.5% efficiency in online mode, even at low loads of 50%. It handles non-linear loads effectively and maintains low harmonic distortion (<1% at resistive loads, <1.5% at non-linear loads), ensuring stable power delivery and optimal system performance.

6.3 Optimizing Efficiency

To maximize efficiency, operate the UPS in ECO mode for non-critical loads and ensure proper ventilation. Regularly inspect and maintain batteries, and adjust settings to match load requirements. Use the high-efficiency online mode for critical applications and keep firmware updated to benefit from performance enhancements and optimizations.

Monitoring and Management

The Sentryum Active-Act 30kVA UPS features advanced monitoring tools, including a 5-inch graphical touchscreen and remote monitoring capabilities, ensuring real-time system oversight and efficient management.

7.1 Remote Monitoring Capabilities

The Sentryum Active-Act 30kVA UPS offers robust remote monitoring capabilities through USB, RS232, and RJ10 communication ports, supporting various protocols for real-time system oversight. This ensures efficient management and immediate response to power events, enhancing overall system reliability and performance.

7.2 LCD Touchscreen Interface

The Sentryum Active-Act 30kVA UPS features a 5-inch graphical touchscreen display for intuitive monitoring and control. The interface provides real-time status updates, configuration options, and event logs, enabling users to manage the UPS efficiently. Its user-friendly design ensures seamless navigation and quick access to critical system information.

7.3 Communication Ports and Protocols

The Sentryum Active-Act 30kVA UPS offers a variety of communication ports, including USB, RS232, and RJ10, ensuring flexible connectivity options. It also supports communication card slots for enhanced remote monitoring and control. These ports enable seamless integration with monitoring systems, providing real-time data and alerts for efficient system management and maintenance.

Safety Precautions and Maintenance

Ensure safe operation by following guidelines in the Sentryum Active-Act 30kVA manual. Regular maintenance, battery checks, and proper handling are crucial for optimal performance and longevity of the UPS system.

8.1 Safety Guidelines

Always disconnect power before performing maintenance. Wear insulated tools to prevent electric shock. Ensure proper ventilation to avoid overheating. Avoid overloading the UPS beyond its rated capacity. Keep the unit away from flammable materials. Follow the Sentryum Active-Act 30kVA manual instructions for safe installation and operation. Regularly inspect for wear and tear. Ensure all connections are secure to prevent faults.

8.2 Routine Maintenance Tasks

Regularly inspect the UPS and batteries for signs of wear or damage. Check battery charge levels and ensure all connections are secure. Clean dust from vents to maintain airflow. Verify insulation integrity and perform firmware updates as needed. Refer to the Sentryum Active-Act 30kVA manual for detailed maintenance schedules and procedures.

8.3 Battery Maintenance Tips

Regularly check battery charge levels and ensure secure connections. Inspect for signs of wear and corrosion. Maintain room temperature below 40°C for optimal performance. Avoid deep discharges and monitor charger current (6A standard). Replace batteries every 5 years or as recommended in the manual.

Troubleshooting Common Issues

Identify issues using the LCD touchscreen and error codes. Check for loose connections and overload conditions. Refer to the manual for diagnostic procedures and solutions.

9.1 Identifying Common Problems

The Sentryum Active-Act 30kVA UPS may exhibit issues like error codes, alarm notifications, or overload conditions. Check for loose connections, battery faults, or excessive load levels. The LCD touchscreen displays diagnostic messages to help pinpoint the root cause of the problem efficiently.

9.2 Diagnostic Procedures

Use the LCD touchscreen to access diagnostic information, including error codes and event logs. Check for alarm notifications and review the battery status. Verify input/output voltages and ensure all connections are secure. Utilize the UPS’s communication ports (USB, RS232) for advanced diagnostics via compatible software tools.

9.3 Solutions for Frequently Encountered Issues

For common issues like error codes or battery faults, refer to the LCD touchscreen for troubleshooting guidance. Ensure communication ports are securely connected. Reset the UPS if necessary. Check battery health and replace if required. Verify input/output voltages match specifications and ensure proper load balancing to prevent overload conditions.

Environmental and Space Considerations

The Sentryum Active-Act 30kVA UPS operates effectively in temperatures up to 40°C with low humidity. Its compact footprint (0.35m²) ensures space efficiency, ideal for data centers or limited areas.

10.1 Operating Conditions

The Sentryum Active-Act 30kVA UPS operates effectively in temperatures up to 40°C with low humidity. It is designed for use in data centers or controlled environments, ensuring reliable performance under standard operating conditions. The system’s components, including dual-core DSP processors and high-frequency inverters, are optimized for efficiency and stability in diverse settings.

10.2 Space and Placement Recommendations

The Sentryum Active-Act 30kVA UPS features a compact footprint of 0.35m², ideal for space-constrained environments. Ensure proper ventilation and maintain clearance around the unit for optimal airflow. Place the UPS on a stable, level surface in a temperature-controlled environment, adhering to the manual’s guidelines for installation and environmental conditions.

10.3 Environmental Impact

The Sentryum Active-Act 30kVA UPS minimizes environmental impact through high energy efficiency, reaching up to 96.5% in online mode. Its eco-friendly design reduces power consumption and carbon emissions, while advanced components ensure reliable operation without excessive cooling demands, promoting a greener power protection solution.

The Sentryum Active-Act 30kVA UPS offers high efficiency, flexibility, and reliability, making it an ideal solution for critical power systems while minimizing environmental impact through advanced technology.

11.1 Recap of Key Points

The Sentryum Active-Act 30kVA UPS delivers high efficiency, with 96.5% efficiency in online mode, unity power factor, and scalability up to 8 units for redundancy. Compact and powerful, it supports non-linear loads, ideal for blade servers and data centers. Advanced components ensure reliable performance, making it a robust solution for critical power systems.

11.2 Final Thoughts and Recommendations

The Sentryum Active-Act 30kVA UPS is a highly efficient, reliable solution for critical power needs. Its compact design, high efficiency, and scalability make it ideal for data centers and blade servers. For optimal performance, ensure proper installation, regular maintenance, and utilize its advanced monitoring features to maximize uptime and energy savings.